Home »
Cryogenic Valve Model C2162-M21
2.0" Vacuum Jacketed Right Angle Valve, Manual Operation
Features
- Low Handle Torque for Bubble Tight Shutoff
- Stainless Steel Stem & Threads
- Redundant Stem Seals
- Cryogenic Stem Packing
- Brass Bonnet
- Redundant Cryogenic Bonnet Seals
- Bonnet Purge Port (Thermal Relief Location)
- All Stainless Steel Body
- Close Tolerance Horizontal Operation OK
- MLI on Jacketed Valves
- Brass Plug
- Plug to Stem Stabilizer
- KEL-F Seat Seal
- Contoured Flow Plugs Available
Technical Data
- 300 PSI MAWP (Maximum Operating Pressure)
- Seat Seal Bubble Tight @ 150 PSIG
- Packing Mass Spec Tested @ 1 x 10-5 Torr
- Leak Rate Below 1 x 10 -9 CC GHe/SEC
- Heat Leak: 27.3 BTU/HR to 20°k
- Cooldown Mass: 10.2 Pounds
- Options:
- Cold Box Jacket
- Pneumatic Actuators
- Purge Port
Applications
- Vacuum Jacketed Piping
- Cold Boxes
- Manifold and Tank Systems
-
Liquid Nitrogen, Helium, Hydrogen, Argon, and Oxygen Service (With Proper Cleaning)